← All tools

Thermal Bridge Estimator

Combine plane, linear, and point heat-loss coefficients in a transparent local model.

Concept estimate only: this tool does not assess code compliance, condensation or moisture risk, HVAC sizing, energy bills, constructability, or construction performance. Geometry, boundary conditions, junction definitions, and coefficient sources must be established by qualified professionals.

Model settings

Plane element

Linear bridge

Point bridge

Portable project

Scenario results

Add elements and calculate.

Baseline vs improved

Formulas

H_plane = A × U; H_linear = L × ψ; H_point = χ; Q = H_total × |Tᵢ − Tₒ|; E = Q × hours / 1000.